Sign In | Join Free | My frbiz.com
China Xi'an Noker Electric Co.,Ltd. logo
Xi'an Noker Electric Co.,Ltd.
Noker Electric, your professional electrical partner !
Active Member

6 Years

Home > Solid State Soft Starter >

Asynchronous Electric Motor Starter Medium Voltage 3 - 10kv Ac High Start Torque

Xi'an Noker Electric Co.,Ltd.

Asynchronous Electric Motor Starter Medium Voltage 3 - 10kv Ac High Start Torque

Brand Name : Noker

Model Number : NKS300-800-10

Certification : ISO9001

Place of Origin : China

MOQ : 1 set

Price : To be discussed later

Payment Terms : L/C, T/T, Western Union

Supply Ability : 300 set per month

Delivery Time : 15-20 work days

Packaging Details : Wooden Packing

Maintenance : Convenient

Communication : Modbus-RTU

Protection : Perfect motor protection

Display : Chinese and English

Start torque : High start torque

Control algorithm : Fuzzy control algorithm

Contact Now

Medium Voltage 3--10kVAC Asynchronous Electric Motor Pump Soft Starter

AC10KV Medium Voltage 800KW Squirrel-Cage Asynchronous Electric Motor Aluminum Zi Soft Starter for Water Pump is a high voltage motor soft starter designed with up-to date concept,and mainly applicable to the control of and protection for the starting and stopping of squirrel-cage type asynchronous ans synchronous motors.The starter is composed of several thyristors in series-parallel,and it can meet different current and voltage requirements.
The product is widely used in electric industry with rated voltage 3000 to 10000V,building materials chemical industry,metallurgy,steel and paper-making industries etc.,and can perform well if used together with various kinds of electromechanical devices including water pumps,fans,compressors,crashers,agitators and conveyer belt etc.,It is the ideal device for starting and protecting high voltage motors.

Technical Indicators

Basic parameters
Type of load Three-phase squirrel cage asynchronous and synchronous motors
AC voltage 3000---10000VAC
Service frequency 50HZ/60HZ±2HZ
Phase sequence CMV is allowed to work with any phase sequence
Composition of major loop (12SCRS,18SCRS,30SCRS depend on model)
Bypass contactor Contactor with direct starting capacity
Control power AC220V±15%
Transient voltage overload protection dv/dt snubber network
Start frequency 1-3 times per hour
Ambient condition Ambient temperature: -20°C -+50°C
Relative humidity: 5%----95% no condensation
Altitude less than 1500m (derating when altitude is more than 1500m)
Protective functions
Open-phase protection Cut off any phase of primary power supply in the course of starting or operation.
Over-current protection in operation Operational Over-current protection setting: 20~500%Ie
Unbalanced phase current protection Unbalanced phase current protection: 0~100%
Overload protection 10A,10,15,20,25,30,OFF
Underload protection Underload protection grade: 0~99%
Action time of underload protection: 0~250S
Start timeout Start time limit: 0~120S
Over-voltage protection When voltage of primary power supply is 120% higher than rated value, over-voltage protection is enabled.
Under-voltage protection When voltage of primary power supply is 70% lower than rated value, under-voltage protection is enabled.
Phase protection Allow to work with any phase sequence (through setting parameter)
Ground protection Protection available when grounding current is higher than set value
Description of communication
Protocol Modbus RTU
Communication interface RS485
Network connection Each CMV can communicate with 31 CMV equipments in network.
Function Operation state and programming can be observed through communication interface.
Operating interface
LCD display LCD display/touch screen display
Language Chinese and English
Keyboard 6 touch membrane keyboard
Meter display
Voltage of primary power supply Display voltage of three-phase primary power supply
Three-phase current Display current of three-phase major loop
Data record
Fault history Record recent 15 faults information
History of number of starts Record number of starts of this soft starter

Catalogue

Voltage Model Rated Current (A) W (mm) H(mm) L (mm)
3000V NKS300-400-3 100 1000 2300 1500
NKS300-630-3 150
NKS300-1600-3 400 1300 2300 1600
NKS300-2500-3 ≥600 Reserved
6000V NKS300-420-6 50 1000 2300 1500
NKS300-630-6 75
NKS300-1250-6 150
NKS300-1600-6 200 1300 2300 1600
NKS300-2500-6 300
NKS300-3300-6 400
NKS300-4150-6 500
NKS300-5000-6 ≥600 Reserved

10000V

NKS300-420-10 30 1000 2300 1500
NKS300-630-10 45
NKS300-800-10 60
NKS300-1250-10 90
NKS300-1500-10 110
NKS300-1800-10 130
NKS300-2250-10 160
NKS300-2500-10 180
NKS300-2800-10 200
NKS300-3500-10 250
NKS300-4000-10 280
NKS300-4500-10 320 1300 2300 1600
NKS300-5500-10 400
NKS300-6000-10 430
NKS300-7000-10 500
NKS300-8500-10 ≥600 Reserved

Connection Diagram

Asynchronous Electric Motor Starter Medium Voltage 3 - 10kv Ac High Start Torque

Asynchronous Electric Motor Starter Medium Voltage 3 - 10kv Ac High Start Torque

Application

Asynchronous Electric Motor Starter Medium Voltage 3 - 10kv Ac High Start Torque

NKS300 series products are designed to be free of maintenance. Like other electric equipments, this equipment should be regularly checked for fear of dust pollution, damp and environmental pollution resulted from industrial production. Serious pollution may result in high voltage discharge and affect the heat dissipation of SCR's cooler.
1 Fault analysis
When a fault occurs, the corresponding fault information will be displayed on LCD touch screen. The motor should be restarted after the fault is cleared. If the fault still can not be cleared using correct operating method and program processing, please contact the manufacturer.
2 Fault code
The soft starter has multiple protective functions. When the protective functions act, the soft starter will stop immediately and the current fault information will be displayed on LCD screen, touch screen and panel. Users can analyze and clear faults according to fault information.

Fault code Fault Cause Troubleshooting
01 Primary power phase loss Phase loss in starting or operation. Check the reliability of three-phase power
02 Phase sequence error Phase sequence reservedly connected. Adjust phase sequence or set phase sequence free of check.
03 Parameters lost Set parameters lost Check functions setting and reset
04 Freq error Poor quality of power grid? Check whether the power quality is found to range?
05 Over-current in operation Load suddenly becomes heavy.
Load variation is too large.
Adjust load running state
Adjust 1M13
07 Unbalanced phase current Phase loss or phase voltage is unbalanced Adjust 1M12
08 Thyristor overheat Internal cooler is overheat
The starter is not well ventilated.
Check the qualification of fan
Lower start frequency
Check if the control power voltage is too low.
09 Internal prohibition Violate operating instruction Ensure operating instruction
10 Start timeout Overburdened and start time is too short.
Current limiting amplitude is too small.
Adjust ramp time 1M04
Adjust current limiting amplitude 1M05
-- Over-voltage protection Power voltage of major loop is higher than set value Adjust over-voltage protection value
Check if primary power voltage if too high.
-- Under-voltage protection Power voltage of major loop is lower than set value Adjust Under-voltage protection value
Check if primary power voltage is too low.
-- Ground protection Ground current is larger than allowed value Check if there is ground current.
-- Frequent start protection Frequent start Reduce start frequency
13 Electronic thermal overload The duration of heavy current is too long.
Overload operation or not.
Check if motor current is wrongly set.
Overload or not.
14 Abnormal SCR SCR works abnormally
Output phase loss for soft starter
Check whether SCR is damaged.
Check whether input or output of soft starter lacks phase.


3 Fault history.
This starter can at most record the recent 15 faults information for users.
4 Troubleshooting
As fault has memory, after fault is cleared, you can reset fault through pressing button "STOP" for above 4 seconds, external fault clearance input terminal (D1 or D2 multifunction input) or cutting off AC220V control power to restore the starter to the state of ready to start.
5 Maintenance
The working field should be regularly cleaned to reduce dust in ambient environment.The low and high voltage bins of NKS300 series high voltage soft starter should be regularly cleaned. It is necessary to use a brush or blower to remove dust inside bin (period less than 20 days)
It is also important to clean thyristor valve block. A blower with big power can be used to clean the valve block by blowing from up to down. Clean the field after blowing the thyristor valve block (period less than 6 months)
To ensure the normal operation, NKS300 series high voltage soft starter should be regularly dehumidified if the working field is wet. (Period is depended on the circumstance)
Considering that there is shake in working field when the soft starter is started, the secondary control wiring of NKS300 series high voltage soft starter should be regularly checked to examine whether the connecting terminal is loose. If yes, tighten the loose connecting terminal. (3 months as a period)

Packaging

Asynchronous Electric Motor Starter Medium Voltage 3 - 10kv Ac High Start Torque


Product Tags:

low voltage metal clad switchgear

      

power distribution cabinet

      
China Asynchronous Electric Motor Starter Medium Voltage 3 - 10kv Ac High Start Torque wholesale

Asynchronous Electric Motor Starter Medium Voltage 3 - 10kv Ac High Start Torque Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Noker Electric Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)
 

Friendly Links: www.everychina.com

Home| Products| Suppliers| Quality Suppliers| Site Map |About Us |Help

Copyright © 2009 - 2024 frbiz.com. All rights reserved.